000 03327nam a22002657a 4500
003 KE-MeUCS
005 20250325103849.0
008 250217b xxu||||| |||| 00| 0 eng d
020 _a0000
040 _cKE-MeUCS
_dKE-MeUCS
050 _aTD426.8.M8 2024
100 _aMuthue, Pauline Ngonyo
110 _aMeru University of Science and Technology
_99593
111 _aMasters thesis
245 _aAssessment of microbial quality of borehole water at source, households and proximity to pit latrines in Ekalakala ward, Machakos county, Kenya :
_ba thesis submitted in partial fulfilment of requirements for the conferment of the degree of Master of Science in Sanitation of Meru University of Science and Technology /
_cPauline Ngonyo Muthue
260 _aMeru:
_bPauline Ngonyo Muthue,
_c2024.
300 _axii, 104p.
504 _aIncludes bibliographic references
520 _aQuality of drinking water is very vital to public health. Diarrhea can be caused by poor hygiene practices, inadequate sanitary action and unsafe drinking water. Globally, 1,000 children die annually due to controllable sanitation - related diarrhea diseases. Furthermore, Africa has been classified as the leading continent in cholera disease due to lack of access to safe clean water and basic sanitation. Kenya is a water scarce country leading to drilling of many boreholes in the country. Almost all the households in Ekalakala ward in Machakos County used borehole water for various activities. This study aimed to determine microbial quality of borehole water and proximity to pit latrines in Ekalakala ward, Machakos County. Mixed methods research design was adopted. The total coliforms were determined using plate count enumeration. The most probable number (MPN) method was used to identify faecal coliforms (Escherichia. coli). Other targeted organisms included Vibrio cholerae and Salmonella spp and were isolated using thiosulfate citrate bile salts and deoxycholate citrate agar respectively. Biochemical test was done on the three microorganisms using the following tests, triple sugar iron, sulphide indole motility, urease test, Simon’s citrate and motility indole urease. The results from coliform forming units indicated high number of bacteria coliforms at 171.3 CFU/100 ml of water. MPN showed that most of the samples were contaminated with faecal coliforms with a mean value of 171.3 MPN/100 ml of water. The results from biochemical tests confirmed the presence of 55% Escherichia coli, 40% Salmonella spp and 55% Vibrio cholerae in both borehole and household water samples. The proximity of boreholes to pit latrines was assessed using a checklist and confirmed that there was moderate positive correlation of (r) = 0.45. Borehole water in Ekalakala ward was contaminated with bacterial coliforms, faecal coliforms and pit latrine proximity was not a big threat to microbial borehole water contamination. Water treatment before use in addition to, education on proper water storage methods by community of health providers should be emphasized.
650 _aWells; Microbiology
650 _aBoreholes; Microbial quality
650 _aMicrobial quality; Boreholes
650 _aMicrobial quality; Boreholes- proximity to pit latrines-Ekalakala ward, Machakos county, Kenya :
942 _2lcc
_cTH
_tSK
999 _c88601
_d88600